FIRE ALARM CERTIFICATE
Fire alarm certificate is a compulsory check for the landlord property in law of BS5839. It is mentioned that all kinds of detectors should be examineat least once in a year by fire alarm certificate specialist. And Fire alarm test should be documented in the log book.
FIRE ALARM CERTIFICATE COST
All landlord Certificates Limited determined to give you best price along with quality service.
Fire Alarm Certificate cost starting £99 including VAT (Residential)
Fire Alarm certificate | Device Quantities | Cost |
---|---|---|
Fire Alarm/ Smoke Alarm/ Fire Detection Certificate | Up to 10 alarms | £89 |
Fire Alarm/ Smoke Alarm/ Fire Detection Certificate | Between 11-20 Alarms | £149 |
THERE ARE TWO GRADE RULES SHOULD MAINTAIN DURING FIRE ALARM INSPECTION.
1. Grade A Fire Alarm system: For the grade A fire alarm system, below mentioned parameter should be checked.
- Heat Alarm Detector
- Smoke Alarm Detector
- Manual Call Board
- Central Control Board
- Bell or Alarm Sound Device
- CO2 Alarm Detector
Also along with Grade A fire alarm system have the following necessities;
Generally A Grade fire alarm system is seen in commercial property, but It can also installed at residential area.
2. Grade D Fire Alarm System
In majority times A Grade D fire alarm system is commonly connected smoke or Heat alarms, maximum times this structure is seen that for the domestic properties.
For the fire alarm certificate have to work out 6 months for the full test.
A full test of the fire alarm system should be carried out every 6 months. The test must be approved by a competent person. The fire alarm assessment should be maintained in accordance with BS5839 part 1 section 6. After right way accomplished of your fire alarm testing, you will get a fire alarm certificate
DAILY CHECKLIST OF FIRE ALARM
- • Alarm panel is in normal set-up
- • Any fault notices to be corrected
- • Visual inspection of panel
Everyone should maintain daily checks, if there is raise any unsolved problem then contact the maintenance fire alarm vendor or company
WEEKLY CHECK LIST OF FIRE ALARM TESTING
- • There also same check as like as daily checklist
- • Make sound an alarm each week, where you can realize sound device is working
properly. If there is seen any difficulties, must contact with concern maintenance team and also make record of that error
FIRE ALARM CERTIFICATE CARRIED-OUT
Fire alarm specialist mainly check the devices in functionally (Battery, Cable Joint) along with check bell or sounder equipment. Then also checked out by integrity, where sound equipment confirm regarding sufficient sound levels in surrounding area.
FIRE ALARM CERTIFICATE TEST RESULTS:
Test Record (inventory all items tested individually along with location)
Test Data Accuracy
Comprehensive guidelines to landlord or landlord agent to stay safety requirements and also maintain those systems)
Log Book (copyrecord all interim routine checks and take actions for any remedial work)
SECURE CABLE TESTING ON THE FIRE ALARM EQUIPMENT:
The cabling of your fire alarm method should also be a checkup. It can be done every 5 years along with EICR electrical certificate. The electrical installation condition report must be finished in line with BS7671